DETAIL IKLAN
565571 views

Jual Fluke 77 IV Digital Multimeter Asia Industri

Jalan D. Musyawarah No. 79a, Jurang Mangu Timur, Pondok Aren, Tangerang Selatan
  • Rp 6.660.000

Fluke 77 IV Digital Multimeter

============================================================

Features

  • Large display
  • Backlight for work in dim areas
  • Min / Max to record signal fluctuations
  • Ergonomic overmolded housing with integrated probe holders
  • Free your hands with the optional TPAK magnetic hanger
  • Auto and Manual ranging
  • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards

============================================================

Specifications

Voltage DC :

- Range : 6.000 V – 1000 V

- Best accuracy : ±(0.3% + 1)

- Best resolution : 0.1 mV

Voltage AC :

- Range : 600.0 mV – 1000V

- Best accuracy : ±(2.0% + 2)

- Best resolution : 1.0 mV

Amps AC :

- Range : 60.00 mA – 10 A

- Best accuracy : 2.5% + 2

- Best resolution : 0.01 mA

Amps DC :

- Range : 60.00 mA – 10A

- Best accuracy : 1.5% + 2

- Best resolution : 0.01 mA

Resistance :

- Range : 600.0 Ω – 50 MΩ

- Best accuracy : ±(0.5% + 1)

- Best resolution : 0.1 Ω

Capacitance :

- Range : 1nF – 9,999 μF

- Best accuracy : ±(1.2% + 2)

- Best resolution : 1 nF

Frequency :

- Range : 99.99Hz – 99.99kHz

- Best accuracy : ±(0.1% + 1)

- Best resolution : 0.01 Hz

Safety : ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV

Certifications : CSA, TÜV (EN61010), Π, (N10140)

General Specifications

Maximum voltage between any terminal and earth ground : 1000 V

Surge protection : 8 kV peak per IEC 61010

Ω Fuse for mA inputs : 440 mA, 1000 V FAST Fuse

Ω Fuse for A inputs : 11 A, 1000 V FAST Fuse

Display :

- Digital : 6000 counts, updates 4/sec

- Bar graph : 33 segments, updates 32/sec

- Frequency : 10,000 counts

- Capacitance : 1,000 counts

Altitude :

- Operating : 2,000 meters

- Storage : 12,000 meters

Temperature :

- Operating : -10°C to + 50°C

- Storage : -40°C to + 60°C

Temperature coefficient : 0.1 x (specified accuracy / °C (< 18°C or > 28°C)

Electromagnetic compatibility (EN 61326–1:1997) : In an RF field of 3 V/M, accuracy = specified accuracy except in temperature: specified accuracy ±5°C (9°F)

Relative humidity (maximum non-condensing) : 90% to 35°C. 75% to 40°C. 45% to 50°C

Battery life : 400 hours typical (alkaline)

Size (H x W x L) : 4.3 x 9 x 18.5 cm

Weight : 420 g

Includes : Installed 9V battery, Test leads, Users manual

===========================================================

UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH

Untuk informasi dan pemesanan, silahkan menghubungi :

Telp. & WA : 62.813.3117.0440

Mail : asiaindustri@gmail.com

============================================================

 

 

Dilihat 71 kali
×
photo profil
Asia Industri
Penjual dan pembeli harus bertemu secara langsung di tempat yang aman untuk melihat barang atau jasa (COD)