DETAIL IKLAN
567381 views

Jual Fluke 106 Palm Sized Digital Multimeter Asia Industri

Jalan D. Musyawarah No. 79a, Jurang Mangu Timur, Pondok Aren, Tangerang Selatan
  • Rp 1.350.000

Fluke 106 Palm-sized Digital Multimeter

============================================================

Features

  • Voltage, resistance, continuity, capacitance
  • Input terminal for ac and dc current measurements to 10 A and current
  • Data hold

============================================================

Specifications

AC volts (40 Hz to 500Hz) :

- Range : 600 V

- Resolution : 0.001 V

- Accuracy : 1.0% + 3

DC volts :

- Range : 600 V

- Resolution : 0.001 V

- Accuracy : 0.5% + 3

AC millivolts :

- Range : 600 mV

- Resolution : 0.1 mV

- Accuracy : 3.0% + 3

Diode Test :

- Range : 2 V

- Resolution : 0.001 V

- Accuracy : 10%

Resistance (Ohms) :

- Range : 40 MΩ

- Resolution : 0.1 Ω

- Accuracy : 0.5% + 3

Capacitance :

- Range : 1000 μF

- Resolution : 0.01 nF

- Accuracy : 2% + 5

Frequency Hz (10 Hz – 100 kHz) :

- Range : 100 kHz

- Resolution : 0.01 Hz

- Accuracy : -

Duty Cycle :

- Range : 1% to 99%

- Resolution : 0.1%

- Accuracy : -

AC current μA (40 Hz to 200 Hz) :

- Range : 10 A

- Resolution : 0.001 A

- Accuracy : 1.5% + 3

DC current :

- Range : 10 A

- Resolution : 0.001 A

- Accuracy : 1.5% + 3

AC volts :

- Overload protection : 600 V

- Input impedance (Nominal) : >10 MΩ <100 pF

- Common mode rejection ratio : >60 dB at dc, 50 Hz or 60 Hz

AC millivolts :

- Overload protection : 600 mV

- Input impedance (Nominal) : >1MΩ, <100 pF

- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz

DC volts :

- Overload protection : 600 V

- Input impedance (Nominal) : >10 MΩ <100 pF

- Common mode rejection ratio : >100 dB at dc, 50 Hz or 60 Hz

- Normal mode rejection ratio : >60 dB at 50 Hz or 60 Hz

DC millivolts :

- Overload protection : 400 mV

- Input impedance (Nominal) : >1MΩ, <100 pF

- Common mode rejection ratio : >80 dB at 50 Hz or 60 Hz

General specifications

Maximum voltage between any terminal and earth ground : 600 V

Display (LCD) : 4000 counts, updates 3/sec

Battery type : 2 AA, NEDA 24A, IEC LR03

Battery life : 200 hours minimum

Temperature

- Operating : 0 °C to 40 °C

- Storage : -30 °C to 60 °C

Relative Humidity

Operating Humidity : Non-condensing when <10°C. ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C

Operating Humidity, 40 MΩ Range : ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C

Altitude : 2000 m, Storage : 12,000 m

Temperature coefficient : 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)

Fuse protection for current inputs : 11A, 1000V Fast Fuse, Fluke specified part only

Size (H x W x L) : 142 x 69 x 28 mm

Weight : 200 g

IP rating : IP 40

Safety : IEC 61010-1, IEC61010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2

Electromagnetic environment : IEC 61326-1: Portable

Includes : TL75 test leads with two caps, 2 AA batteries, User’s manual

===========================================================

UNTUK MENGHINDARI PESANAN BARANG ANDA DITOLAK OLEH KAMI, SILAHKAN BERTANYA STOCK BARANG TERLEBIH DAHULU. TERIMA KASIH

Untuk informasi dan pemesanan, silahkan menghubungi :

Telp. & WA : 62.813.3117.0440

Mail : asiaindustri@gmail.com

============================================================

 

Dilihat 81 kali
×
photo profil
Asia Industri
Penjual dan pembeli harus bertemu secara langsung di tempat yang aman untuk melihat barang atau jasa (COD)